DADANCODADANCO
NewsContactPress RoomJobsCompany ProfileProductsApplicationsProjectsFAQHome

  Products
  Active Chilled Beams
  Induction Units
      Overview
      Starline CM10
      Starline FM30
      Starline HM30
       
  Induction Diffuser - INFFUSER
  Refurbishment Kits
  Independent Reports
     
     
     
PROUDLY AUSTRALIAN
Proudly Australian
OWNED, DESIGNED, MANUFACTURED AND SUPPORTED


  Induction Units
CM10 - Ceiling Mounted Induction Unit
    Ceiling Mounted Chilled Beam
   
EuroVent Certification

Dadanco Pty Ltd participates in the ECC programme for Chilled Beams. Check ongoing validity of certificate: www.eurovent-certification.com or www.certiflash.com

* models so marked are not ECC certified  


New DADANCO STARLINE Induction Units, available in a wide range of capacities and dimensions, can replace induction units as well as fan coil units in existing perimeter air conditioning systems or be incorporated into new systems.

  Product Documentation

UPDATED! Starline CM10 2-page brochure (PDF 277k)
UPDATED! Starline CM10 Product Information (PDF 904k)
DADANCO Induction Units Solutions Delivery White Paper (PDF 169k)
UPDATED! *Starline HM/FM30 2-page brochure (PDF 1.32M)
UPDATED! *Starline FM30 Product Information (PDF 1.38M)
UPDATED! *Starline HM30 Product Information (PDF 543k)

  Installation and Maintenance Manuals

UPDATED! Starline CM10 Installation and Maintenance Manual (PDF 411k)
UPDATED! *Starline FM30 Installation and Maintenance Manual (PDF 491k)
UPDATED! *Starline HM30 Installation and Maintenance Manual (PDF 335k)

  Overview

The innovative STARLINE range of perimeter zone induction terminal units incorporates DADANCO patented multi-lobe nozzles for higher efficiency and maximum performance per litre/second of primary air.

The profiled-wall mixing chamber arrangement produces the same, if not better, air conditioning efficiency as any other air conditioning system but with more flexibility.

STARLINE terminal units provide a cost competitive, energy efficient, low maintenance air conditioning solution for building refurbishments or new construction where higher energy efficiency is a design consideration.

STARLINE perimeter units increase the entrainment of secondary room air by up to 77% resulting in a 50% increase in capacity, and achieve noise levels as low as NR28. For a given primary airflow, noise can be decreased between 5 and 10dB compared to older generation induction units.

Individual or group unit control - Every office or meeting room on every floor served with STARLINE units can be individually controlled to suit individual needs.

In new buildings, the installed space reduction provided by the smaller infrastructure needed for STARLINE induction terminal units translates into reduced slab-to-slab clearance which can accumulate to create an extra floor for every 12 conventional floors.

In existing induction unit systems, floor mounted units can be replaced with new STARLINE ceiling mounted units, recovering valuable lettable space.

As there are no moving parts in STARLINE perimeter induction units, maintenance is minimised to annual inspection and cleaning.

  New Technologies

Novel high performance multi-lobe nozzles and superior fluid dynamic design combine to deliver higher cooling performance at lower primary air pressures in STARLINE terminal air conditioning units.

Compared to concealed space fan-coil units, STARLINE terminal air conditioning units use primary air and not a fan to induce secondary room air through the cooling coil within the unit for energy efficient, quiet and vibration free operation. Efficient air induction process delivers higher secondary cooling capacities for NO ADDITIONAL FAN POWER REQUIREMENT.

State-of-the-art computational fluid dynamic (CFD) analysis is used by DADANCO in the design of STARLINE terminal air conditioning units to develop improved unit geometry and for the prediction of STARLINE terminal air conditioning unit performance.


  Advantages of STARLINE Terminal Units

STARLINE terminal units supply higher cooling and heating performance for as little primary air as is needed to satisfy the outside air ventilation requirements in the conditioned space.
Deliver higher capacities for less air to help achieve higher NABERS and green star ratings.
Compact dimensions and intrinsically smaller primary air duct sizes offer real savings in space requirements compared with conventional all-air air conditioning systems.
Fan power is dramatically reduced. STARLINE terminal units deliver more cooling capacity using less treated air than any all-air system.
Higher secondary air entrainment rates mean increased secondary cooling for NO ADDITIONAL FAN POWER REQUIREMENT.
STARLINE terminal units provide improved constant volume air distribution to the conditioned space.
Noise radiated from STARLINE terminal units is inherently low compared to most induction units, helping to achieve space noise levels below the values recommended for quality office and other spaces, including audio visual conference rooms.
Offer a cost-effective means of upgrading HVAC systems by adding the latest air conditioning technology to existing ductwork, on-floor infrastructure and controls.
Can be fitted easily into existing primary air systems and tight ceiling spaces.
STARLINE terminal units have no moving parts and require minimal maintenance.
Feature simple, low maintenance, reliable design.

  Dadanco Unit Configurations:


STARLINE CM Ceiling mounted down discharge unit with compact dimensions for installation in restricted spaces.
*STARLINE FM Floor mounted upward discharge unit for installation in parapet enclosures below window sill level.
*STARLINE HM Horizontally mounted unit, installed in a drop ceiling space or a bulkhead, designed to discharge air horizontally for use in hotel rooms, atriums & foyers or installations where ceiling space is not available.