  Active Chilled Beams
  Induction Units
      Overview
      Starline FM30
      Starline CM10
      Starline HM30
      Compare and Decide
     
  New Inffuser Range
  Refurbishment Kits
  Independent Reports


  Induction Units: Starline FM30/HM30


Terminal air conditioning units
Specifications: FM30/HM30
     
Cooling Capacity 25 to 250 W/m2
  Length 700 - 2000mm
  Instalation FM30 - 495mm
  Height HM30 - 350mm
(with drip tray)
  Insulation Thermal insulation for the primary air plenum & condensate tray is optional
  Grille Requires supply grille. Return air through grille
or concealed gap.

  STARLINE FM/HM terminal air conditioning units incorporate new patented technologies and are hailed as a breakthrough for air conditioning worldwide.

STARLINE FM/HM terminal air conditioning units provide efficient, effective and whisper-quiet air conditioning.
Download STARLINE FM 30/HM 30
(PDF file 220k )

  New Technologies

Novel high performance nozzles and superior fluid dynamic design, combine to bring STARLINE FM/HM terminal air conditioning units into the 21st century.
As opposed to concealed space fan-coil units, STARLINE FM/HM terminal air conditioning units use primary air and not a fan to induce secondary room air through the cooling coil within the unit, for energy efficient, quiet and vibration free operation.

State-of-the-art computational fluid dynamic (CFD) analysis is used by DADANCO during the design of STARLINE FM/HM terminal air conditioning units. Computational fluid dynamics (CFD) is being used for the prediction of the performance of STARLINE
FM/HM terminal air conditioning units in actual installations as well.

  Advantages of STARLINE FM/HM units

STARLINE FM/HM terminal air conditioning units supply cooling, heating and the outdoor air required for ventilation in the conditioned space.
Compact dimensions and intrinsically small primary air duct sizes offer real savings in space requirements compared with conventional all-air air conditioning systems.
Fan power is dramatically reduced. The primary air is treated in a plant room and distributed at low pressure. The primary air is typically only 30% of the air supplied by STARLINE FM/HM terminal air conditioning units. STARLINE FM/HM terminal air conditioning units deliver more cooling capacity using less treated air than any all-air system.
STARLINE FM/HM terminal air conditioning units provide good air diffusion in the conditioned space.
Noise radiated from STARLINE FM/HM terminal air conditioning units is very low, and helps to achieve space noise levels below the values recommended in relevant standards and codes for quality office and other spaces, including audio visual conference rooms (e.g. AS 2107).
STARLINE FM/HM terminal air conditioning units require minimal maintenance.